Denoising Multiphase Functional Cardiac CT Angiography Using Deep Learning and Synthetic Data (study dataset)
2025-11-29https://doi.org/10.1148/atlas.1764447575897
42
Overview
Schema Version
https://atlas.rsna.org/schemas/2025-11/dataset.json
Name
Denoising Multiphase Functional Cardiac CT Angiography Using Deep Learning and Synthetic Data (study dataset)
Link
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10982910/
Indexing
Keywords: Cardiac CT Angiography, Deep Learning, Image Denoising, Left ventricular function, Retrospective gating
Content: CA, CT, RS
RadLex: RID11224
Author(s)
Veit Sandfort
Martin J. Willemink
Marina Codari
Domenico Mastrodicasa
Dominik Fleischmann
Organization(s)
Department of Radiology, Stanford University School of Medicine
Funding
Authors declared no funding. Acknowledgments note support from the Stanford Radiology Department Radcombinator program and computer support from the Stanford 3D and Quantitative Imaging Laboratory.
Ethical review
HIPAA-compliant retrospective study approved by the institutional review board; requirement for patient consent was waived due to use of anonymized data.
Date
Published: 2024-02-28
References
[1] Sandfort V, Willemink MJ, Codari M, Mastrodicasa D, Fleischmann D. "Denoising Multiphase Functional Cardiac CT Angiography Using Deep Learning and Synthetic Data". Radiology: Artificial Intelligence. 2024-02-01. doi:10.1148/ryai.230153. PMID: 38416035. PMCID: PMC10982910.
Dataset
Motivation
Enable use of high-noise functional phases from dose-modulated retrospectively gated coronary CTA by denoising to facilitate valid LV functional measurements.
Sampling
566 consecutive adult patients undergoing coronary CTA with dose-modulated retrospective gating.
Partitioning scheme
Split per patient 80:10:10 into training, validation, and test. Resulted time series counts: 29,699 (train), 3,087 (validation), 3,325 (test).
Missing information
Due to anonymization, specific patient characteristics (e.g., demographics) were not available for correlation.
Relationships between instances
Each patient has multiphase time series (10 frames); synthetic low-noise time series created by deforming the lowest-noise frame to match higher-noise frames using nonrigid registration.
Noise
High time-variable noise in dose-modulated phases; synthetic low-noise labels generated via nonrigid coregistration for training.
External data
No external datasets reported; all data acquired at a single center with a single vendor scanner.
Confidentiality
Anonymized clinical imaging data; IRB approved; HIPAA compliant.
Re-identification
Data were anonymized; no patient-level identifiers available.
Sensitive data
Clinical cardiac CT images of adult patients; anonymized.